Type PBM-1170-05-V0060

121 mm
Typ PBM-1170-05-V0060 von E-T-A: für die Aufnahme von thermischen Schutzschaltern des Types 1170-21, 1180 und 1610 konzipiert

Description

The power distribution system has been designed to accommodate plug-in type thermal circuit breakers type 1170-21, 1180 and 1610. It is a printed circuit board module for rail mounting. Typical applications are mainly in control cabinets for utility vehicles and special vehicles and for mobile construction machinery.

Technical Data

Mounting method DIN rail
Circuit breaker type thermal
Max. rated voltage DC +12 V
DC +24 V
Number of channels 1 x 16 non-redundant
Supply non-redundant
Supply max. current rating 100 A single pole
Supply terminal type 10 mm²
16 mm²
Spring-loaded terminals
Max. current rating of loads 20
Terminal type of loads 2.5 mm²
4 mm²
Spring-loaded terminals
Signalling Break contacts connected in parallel
Terminal type of auxiliary contacts 1.5 mm²
Operating temperature range -20 ... +70 °C
Further technical data  are available upon request 

Applications

  • Automation
  • Automobiles
  • Commercial Vehicles
  • Rail vehicles
  • Watercraft & Vehicles

Downloads

Datasheet & Explanations